[Nagiosplug-devel] [ nagiosplug-New Plugins-1089005 ] Monitor temperature on Cisco 7200

SourceForge.net noreply at sourceforge.net
Tue Dec 21 05:04:11 CET 2004


New Plugins item #1089005, was opened at 2004-12-21 14:03
Message generated for change (Tracker Item Submitted) made by Item Submitter
You can respond by visiting: 
https://sourceforge.net/tracker/?func=detail&atid=541465&aid=1089005&group_id=29880

Category: None
Group: None
Status: Open
Resolution: None
Priority: 5
Submitted By: Kresimir (omadon)
Assigned to: Nobody/Anonymous (nobody)
Summary: Monitor temperature on Cisco 7200

Initial Comment:
Plugin for Nagios monitors temperature in Cisco 7200 
series routers using Net::SNMP.

Cisco 7200 reports 4 temperatures (inlet, outlet1, 
outlet2, outlet3),
on my router outlet2 and outlet3 are the same. This is a 
very good
way to monitor air condition in server room...

CISCO-ENVMON-
MIB::ciscoEnvMonTemperatureStatusDescr.1 = STRING: 
chassis inlet
CISCO-ENVMON-
MIB::ciscoEnvMonTemperatureStatusDescr.2 = STRING: 
chassis outlet 1 
CISCO-ENVMON-
MIB::ciscoEnvMonTemperatureStatusDescr.3 = STRING: 
chassis outlet 2 
CISCO-ENVMON-
MIB::ciscoEnvMonTemperatureStatusDescr.4 = STRING: 
chassis outlet 3 
CISCO-ENVMON-
MIB::ciscoEnvMonTemperatureStatusValue.1 = Gauge32: 
22 degrees Celsius
CISCO-ENVMON-
MIB::ciscoEnvMonTemperatureStatusValue.2 = Gauge32: 
24 degrees Celsius
CISCO-ENVMON-
MIB::ciscoEnvMonTemperatureStatusValue.3 = Gauge32: 
26 degrees Celsius
CISCO-ENVMON-
MIB::ciscoEnvMonTemperatureStatusValue.4 = Gauge32: 
26 degrees Celsius
or
1.3.6.1.4.1.9.9.13.1.3.1.3.1 = Gauge 32 22 degrees 
Celsius
1.3.6.1.4.1.9.9.13.1.3.1.3.1 = Gauge 32 24 degrees 
Celsius
1.3.6.1.4.1.9.9.13.1.3.1.3.1 = Gauge 32 26 degrees 
Celsius
1.3.6.1.4.1.9.9.13.1.3.1.3.1 = Gauge 32 26 degrees 
Celsius

----------------------------------------------------------------------

You can respond by visiting: 
https://sourceforge.net/tracker/?func=detail&atid=541465&aid=1089005&group_id=29880




More information about the Devel mailing list